Troubleshooting the Manager30 S2's intermittent charging issue

The Manager30 S2 can appear to charge intermittently due to voltage drop on the input line. 

 

For fixed-voltage alternators, it switches off every 100 seconds to check start battery voltage, shutting down if it sees below 12.7V and only restarting when voltage rises above 13.2V. 

 

Extra loads on the same supply line, undersized cabling, poor connectors, or long-term use of Anderson plugs can exaggerate voltage drop and prevent it from turning back on. Using thicker cable, clean secure connections, and MIDI fuses helps. 

 

If issues persist, the system can be rewired to Ignition input mode (as for smart alternators) to bypass the effect of voltage drop. For vehicles with smart alternators, the Ignition trigger setup is mandatory.

 

REDARC recommends seeking the support of a qualified auto electrician or technician.

Important

For your safety, REDARC recommends installation by a qualified auto electrician or technician. Our trusted REDNetwork is made up of professional auto electrical businesses certified by REDARC to install the complete of REDARC solutions. Find Your Local Installer

This information is applicable to the following products: 

  • Manager30 S2 Battery Management System

For Fixed Voltage or Temperature Compensating alternators

When the DC Input Trigger is set to “12V”, the BMS1230S2 turns off at 12.7V but operates down to 9V. The reason for the two figures is that, while it is running, the current drawn by the BMS1230S2 causes a voltage drop along the line from the start battery. It is designed to still charge effectively even when the voltage drop is so extreme as to produce only 9V at the BMS1230S2 input  even though the actual start battery may be well above the “turn off” voltage (allowing for a very long cable run). Every 100 seconds, the BMS1230S2 switches off briefly, (eliminating the voltage drop) and checks the input voltage (effectively measuring actual start battery voltage). If it is still above the “turn off” voltage, it switches on again. The cycle is repeated until the battery voltage is below the “turn off”, in which case the BMS1230S2 stays off. It will only turn on again when it senses the start battery is above the “turn on” voltage of 13.2V when is charging.

If there is additional load on the line to the BMS1230S2 (as can be found for example, when a 3 way fridge and the BMS1230S2 are both being supplied via the same cable and Anderson plug from the start battery) the fridge alone can cause enough voltage drop to cause the BMS1230S2 to see less than 12.7V when it does its 100 second check. In this case it will not switch back on unless (in this example) the fridge cycles off.

To alleviate this problem, first check:

Important

In this article we explain the need for testing to determine the cause of the issue. Testing may involve changes to the installation or wiring. For your safety and accuracy, REDARC recommends engaging a REDNetwork member or a suitably qualified auto electrician - Find Your Local Installer

  • Check that the alternator is keeping your start battery to at least 13.5V.
  • Cable thickness. For the BMS alone we recommend at least 6AWG (13mm2) wire for more than a 3 metre run (see page 17 of the BMS1230S2 Instruction Manual). If the cable is being shared with another load, you should have at least 4AWG (21mm2) wire.
  • Connectors. Ensure that all connections (terminal to wire, wire to wire Etc) are cleanly crimped and/or soldered.
    Plugs. Anderson plugs are not recommended for long term connection. They are meant for applications where they will be unplugged & reconnected occasionally, as this process makes the contacts “wipe” each other clean of any contamination or tarnishing that can build up in this style of connector. If an Anderson plug has been plugged in for an extended time, unplug it and spray with WD40 Etc. before reconnecting.
  • Fuses. We strongly recommend the use of MIDI style fuses. Other types are prone to poor contact and can eventually cause overheating and melting even well below the fuse rating. For more on this, see Bad fuses? Or bad fuse holders? 

If none of these points apply, it is possible to ignore the voltage drop by rewiring as if you had a Variable Voltage “smart” alternator. To do this, change the input trigger to “Ignition”, and either run a line from vehicle ignition to pin 4 of the BMS green plug or from park lights to pin 4 (and remember to keep park-lights on when you want he BMS charging) OR by adding a link from pin 4 over to pin 6 of the green plug on the BMS and an ignition controlled relay or solenoid to supply power from the start battery to the BMS (see How to wire a BMS1230S2 from caravan to vehicle with Variable Voltage alternator).  

For a Variable Voltage “smart” alternators

The BMS operates in a similar way to the other alternator systems except that it turns off at 11.9V (still works down to 9V), with the same 100 second test cycle. With a “smart” alternator, the input trigger must be set to Ignition and wired as described above. (see How to wire a BMS1230S2 from caravan to vehicle with Variable Voltage alternator).  

If this has been done correctly, check the same points as listed above for other alternator systems.

Was this article helpful?
0 out of 0 found this helpful