Articles in this section

How to change the REDWorks battery type

The process for changing the battery type on REDWorks Scout, Nomad and Pioneer panels depends on the model, but all require confirming the battery can safely accept the selected charging profile. 

Scout25, Scout40 and Nomad40 units are adjusted manually by removing the cover, accessing the wiring and selecting a profile that matches the battery’s specifications. 

Scout50 and Nomad50 allow changes either through the control button on the BCDC or via Bluetooth® using the RedVision or Configurator app, with AGM and Calcium options requiring the app. 

The Pioneer50 offers the most flexibility, letting users change the battery type through the control button, the RedVision screen or Bluetooth® apps, and also allows battery size configuration through the screen or apps. Correct profile selection is critical to avoid overcharging or damaging the battery.

Important

For your safety, REDARC recommends installation by a qualified auto electrician or technician. Our trusted REDNetwork is made up of professional auto electrical businesses certified by REDARC to install the complete of REDARC solutions. Find Your Local Installer

This information is applicable to the following products:  

  • REDWorks Scout25 (ICMS-015-001) 
  • REDWorks Scout40 (ICMS-015-002) 
  • REDWorks Scout50 (ICMS-015-003) 
  • REDWorks Nomad40 (ICMS-016-002) 
  • REDWorks Nomad50 (ICMS-016-002) 
  • REDWorks Pioneer50 (ICMS-017-001) 

Before changing the battery type, first ensure the battery can be charged at the applicable charge rate relative to the charger. 

Scout25/40 & Nomad40

1. Remove the powder coated steel cover.

2. Locate the small green and orange wires, they will be connected to the Wago™ connector. 

3. Review profile suitable for your battery, If the battery doesn’t specify contact the battery manufacturer.

Orange wire connection on the BCDC
Charge profile selection table

CAUTION: 

Check the manufacturer’s data for your battery and ensure that the Maximum voltage of the Charging Profile you select does not exceed the manufacturer’s recommended maximum charging voltage. If the Maximum voltage is too high for your battery type, select another Charging Profile. 

The Heated Lithium (H) charging profile should only be used with lithium batteries that feature a functioning heating element. If unsure, the standard Lithium (Li) charging profile must be used. Using the wrong charging profile may damage your lithium battery.

Scout50 & Nomad50

There are 2 ways to Set the Battery Type on the Scout50/Nomad50. 

NOTE: The battery size can only be set up via the REDARC User or Configurator App.

Option 1

1. Remove the powder coated steel cover to set the battery type with the Control Button on the BCDC.

2. Press and hold the Control Button until it turns green, then press the Control Button to cycle through settings until it is flashing pink. 

3. Press and hold the Control Button until the LED is solid pink to enter the Profile Select setting.  

4. Press the Control Button to cycle through the Charging Profiles, indicated on the Charge Profile LEDs. 

5. To confirm the chosen setting, press and hold the Control Button until it rapidly flashes pink. After 10 seconds of no input, the Control Button LED will automatically turn off. 

NOTE: If wanting to set to an AGM or Calcium Battery it will require option 2.

BCDC Alpha light indication

Option 2

Use the Bluetooth® connection (see Bluetooth® connection Tech Tip) on the BSEN500 and connect via the REDvision User or Configurator app.

This option is also the only way to set up the battery size.

Pioneer50

There are 3 ways to set the Battery Type on the Pioneer50.

Option 1

1. Remove the powder coated steel cover to set the battery type with the Control Button on the BCDC.

2. Set via the Control Button 

3. Press and hold the Control Button until it turns green, then press the Control Button to cycle through settings until it is flashing pink. 

4. Press and hold the Control Button until the LED is solid pink to enter the Profile Select setting.  

5. Press the Control Button to cycle through the Charging Profiles, indicated on the Charge Profile LEDs. 

6. To confirm the chosen setting, press and hold the Control Button until it rapidly flashes pink. After 10 seconds of no input, the Control Button LED will automatically turn off. 

Option 2

Set via the RedVision Screen.

Find charger settings in the Settings Menu, select the battery icon on the LH side. Use the Left and right hand Arrows to adjust the battery type. Using the up and down arrows you can then set the battery size. Before selecting the green tick in the top RH Corner, it will then ask you to confirm select the green tick again. 

Night mode not applicable with Pioneer50.

RedVision screen with battery chemistry.
RedVision screen with battery chemistry.

Option 3

Use the Bluetooth® connection (see Bluetooth® connection Tech Tip) on the BSEN500 (or Screen) and connect via the REDvision User or Configurator app, noting the Configurator App will be needed to configure the TVMS Rogue (TVMS1240).

Using the REDARC User App: 

1. Select the 3 lines in the RH top Corner 
2. Select Battery Configuration 
3. Select drop down next to battery type, select battery type  
4. Select Save 

RedVision app interface

Using the REDARC Configurator App:

1. Select Battery Sensor 
2. Select drop down next to battery type, select battery type  
3. Select Save 
4. Select Program, then the RedVision Pro Display or BSEN

RedVision configurator app.
Was this article helpful?